기본 정보
보호
Overvoltage Short Circuit Overcurrent Unbalanced
신청
Fire Safety Defence Communication Spaceflight
원산지
Shenzhen Guangdong China
제품 설명
Online UPS Output Power Factor 10kVA
modelMZT9830L | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 150KVA | 200KVA | 300KVA | 400KVA |
Nominalcapacity(KVA) | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 300 | 400 |
Singe-phase maximum current input(A) | 19 | 29 | 38 | 57 | 76 | 114 | 152 | 189 | 227 | 303 | 379 | 568 | 609 |
Works as well as the principle | On-line power supply,static bypass switch(uninterrupted switch)double conversion technology |
Ac input parameters | Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±25% |
Nominal frequency | 50Hz±10%,60Hz±10% |
The voltage harmonic distortion | <10% |
Soft sart | 0-100%5sec |
bypass | Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±15% |
Nominal frequency | 50Hz/60Hz±10% |
Inverter/bypass(conversin) | 0ms |
The battery | Number of battery unit | 30knots/12v series |
Nominal battery voltage | 360V |
maximum discharge current(A) | 25 | 38 | 51 | 76 | 101 | 152 | 203 | 253 | 305 | 405 | 550 | 760 | 1015 |
Float chargin voltage | 405V(3 months automatic battery to charge,charge voltarge voltage 435V) |
Charging curret | 1A-5A(according to battery capacity setting) |
inverter | The load power factor | 0.8(0.9optinal) |
Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±1%(The steady-state load),380VAC±3%(The load fluctuation |
Nominal frequency | 50Hz±0.05%,60Hz±0.05%(Battery power) |
Frequency stability:when not in sync | <±0.05% |
When the frequency stability:synchronization | <±5% |
Output waveform | Sine wave |
Total harmonic distortion | Lindar load<2%:The nonlinear load<4% |
Dynamic load voltage transients | <5%(from 0 to 100% more |
Transient recovery time | <10ms(±5%) |
Unbalanced voltage | <±1%(Balance the load voltage),<±3%(Unbalanced load) |
Overload capacity | Overload for ten min later turn the bypass,125% 150%overload lasts1 min after bypass |
The inverter efficiency and load by 100% | 95% |
The system structure | Total efficiency of 100% load | 91%,95%.ECO |
Computer ommunication interface | Rs232,(Rs485.Network remote monitoring software) |
Operating temperature | 0-40ºC |
Relating humidity | 0-90% Without any condensation |
Running high | <1500m(each additional,100meters power fell by 1%, the highest4000meters |
Cooling way | Forced vention(temperature control) |
Noise(db) | <65 |
The body color | black |
The input cable | The bottom/bcak |
Easy to maintain | On/about/in front of the plane can be opened |
Lnput device | Terminal row |
The output device | Terminal row |
Size (D×W×H) | 725×450×1135 | 855×450×1235 | 715×855×1500 | 1100×900×1700 | 1200×1500×1800 | 1300×1800×1800 |
The host weight(kg) | 200 | 250 | 340 | 400 | 480 | 650 | 900 | 1200 | 1300 | 1480 | 2000 | 2100 | 2500 |
Option to | Rs485,weaver board,network management system,battery testing sydstem,lightning protection devices for option |
is required to order |
The characteristics of 3C3 series Three-phase input and output High frequency on-line UPS : Adopted double conversion design, To provide a safe and reliable power supply for the followingsituation: The grid without power, mains voltage too high or too low, instantaneous voltage drop ordamped oscillation, high voltage pulse, voltage fluctuation, surge voltage, harmonic distortion,noise interference, the condition of frequency fluctuations, etc. This product is widely used in sm alland medium sized data center, network management center, enterprise server room and generalindustrial environmentsN+X parallel connection redundancy : The machine has the function of parallel connection, Don'tneed to increase the external accessories, Can achieve the maximum of 6 ~ 8 UPS parallel, The user canbe low cost system expands, N for load required the fewest number of UPS, X represents the numberof redundant , The greater the X system reliability will be higher, Adopts the advanced control strategy,In weaver redundant work condition, the system can support sharing a set of batteries, save theinvestment cost of users,The intelligent battery charge and discharge management: Advanced intelligent charging waysthrough the control of the CPU, according to different environmental conditions, Fixed chargingparameters, Provide the best way of charging the battery, Design a variety of charging ways, accord ingto the type of battery, battery section number and the stat us of the battery to choose the best way ofcharging. Scientific way of charging, to prolong the service life of the battery., And can be addedwiththe charging unit, make many battery back charging time is shortened greatly.Positive and positive operation maintenance function: Give full consideration to the user spaceeffective utilization; Modular design and the positive maintenance, greatly shorten the troubleshoo tingof the machine time, improve the usability of UPS.Provide the ECO mode ,whole machine efficiency reached 93% ~ 94%, Reduce the UPS power loss;Can adapt to bad power grid environment.Excellent input frequency range make UPS can adapt todifferent power supply devices,IGBT High frequency intelligent rectifier inverter technology, The input power factor above 0.99, T heinput current harmonic as low as 3%; The output voltage current performance is more outstanding.Strong ability of overload: 110-125% of load can be normal operation for 10 minutes, 125-150% of loadcan be normal operation for 1 minute. And it have Output short circuit protection ability. Welcome your enquiryContact me :Shawn Zhang
주소:
Floor 9, Building3, Jincheng Park, Dalang Street, Longhua District, Shenzhen, China
사업 유형:
제조사/공장
사업 범위:
가전제품, 건축과 장식재료, 공업 설비와 부품, 안전과 방호, 야금광산물과 에너지, 전기전자, 제조 가공 기계, 조명, 측정 기계, 컴퓨터 제품
경영시스템 인증:
ISO 9001
회사소개:
Mize Company는 1999년에 설립되었으며 현재까지 포괄적인 전원 공급 업체로 발전해 왔습니다. 여기에는 UPS 무정전 전원 공급 장치, 마이크로컴퓨터 비접촉 전자 AC 규제 전원 공급 장치, EPS 긴급 전원 공급 장치 등이 포함됩니다. 주요 제품군: 금융, 정부, 연구 기관, 운송, 항공 우주, 전력 장비에 대한 전 세계 전자 및 통신 산업을 충족시키기 위해 개발 필요성 때문에 시장의 수요가 점점 더 활발해지고 있습니다. Shenzhen Meze power technology Co., Ltd는 2008년에 설립되었습니다(UPS 전원 주파수 전문, 규제 전원 공급, 및 변압기)는 같은 해 Meze Electronics Co., Ltd.(터미널 블록, 모든 PCB 부속품)에 등록했으며 2011년에는 Shenzhen Meze Mechanical and Electrical Co., Ltd.(SMT 배치 기계 및 부속품)를 등록했습니다.
기존 직원 수: 180-180 직원이 3000평방 미터를 사용하는 이 회사는 기술과 풍부한 경험을 보유하고 있으며, 잘 알려진 유럽 브랜드의 제품을 통해 고객에게 고품질의 고성능 고안정성 전원 공급 장치 보호 기능을 제공하는 데 최선을 다하고 있습니다. 국제 고급 지능형 디지털 UPS 전원 공급 장치 기술과 가장 진보된 정밀 정제를 사용합니다. 최첨단 최첨단, 가장 안정적인 최고의 전력 솔루션을 제공합니다.