기본 정보
모델 번호.
CU/XLPE Insulation/Steel Wire Armoured/PVC
모델
Cu/XLPE Insulation/Steel Wire Armoured/PVC
Armoured Layer
Steel Wire
제품 설명
1,APPLICATION
YJV32-Copper Conductor XLPE Insulated Steel Wire Armoured PVC Sheathed Power Cable
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 26/35KV
 
2,BASIC INFORMATION
Code Name 
YJV32
Rated Voltage (Uo/U)
26/35KV
Cable Structure
Copper Conductor/XLPE Insulation/Steel Wire Armoured/PVC Sheath
 
 
3,CONSTRUCTION
Conductor
Number of conductors:1,3
The conductors shall comply with the requirement given in IEC
Insulation
XLPE(Cross-linked Polyethylene) according to IEC
Sheath
PVC(Polyaluminium Chloride) according to IEC
Metal screen
Copper Tape Screen
Armoured Layer
Steel Wire
 
 
4,CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.
 
 
5,CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 90ºC
Max.short-circuit temperature
Maximum shall not exceed 250ºC(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Minimum bending radius
The bending radius of cable: (D-Diameter of cable) 
For Three Core Cable-------------------------------------≥15D
For Single Core Cable-------------------------------------≥20D
 

6,Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.
Where:
Uo-The rated power-frequency voltage between conductor and screen or metallic-sheath,for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed:
Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.
 
7,Rated voltaged of cable applied in three phrase system are given in table


U | 
Um | 
Uo |

First class | 
Second class |

1 | 
1.2 | 
0.6 | 
0.6 |

3 | 
3.6 | 
1.8 | 
3.6 |

6 | 
7.2 | 
3.6 | 
6 |

10 | 
12 | 
6 | 
8.7 |

15 | 
17.5 | 
8.7 | 
12 |

20 | 
24 | 
12 | 
18 |

35 | 
42 | 
21 | 
26 |

Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.
The second class cable suitable fir more earth-fault time and more better insulation performance.
 
8,Production Range of cable


Type | 
No. of cores | 
Nominal Cross sectional area m2 |

Aluminum alloy conductor |

YJV32
 | 
1 | 
25-630 |

3 | 
25-630 |

*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied. |




 
9,DIMENSIONS-YJV32-26/35KV


Nominal cross sectional area of conductor(mm²) | 
Nominal insulation thickness(mm) | 
26/35KV YJV32 |

Approx overall diameter(mm) | 
Cable weight max(kg/kn) |

1×50 | 
10.5 | 
46.9 | 
4030 |

1×70 | 
10.5 | 
48.4 | 
4380 |

1×95 | 
10.5 | 
50.3 | 
4830 |

1×120 | 
10.5 | 
51.9 | 
5250 |

1×150 | 
10.5 | 
53.7 | 
5730 |

1×185 | 
10.5 | 
55.2 | 
6160 |

1×240 | 
10.5 | 
57.9 | 
6940 |

1×300 | 
10.5 | 
60.3 | 
7810 |

1×400 | 
10.5 | 
63.7 | 
8990 |

1×500 | 
10.5 | 
68.8 | 
10500 |

1x630 | 
10.5 | 
72.6 | 
12080 |

3×50 | 
10.5 | 
91.9 | 
12620 |

3×70 | 
10.5 | 
95.5 | 
13820 |

3×95 | 
10.5 | 
99.6 | 
15360 |

3×120 | 
10.5 | 
103.0 | 
16700 |

3×150 | 
10.5 | 
106.6 | 
18280 |

3×185 | 
10.5 | 
110.0 | 
19595 |

3×240 | 
10.5 | 
115.2 | 
22105 |

3×300 | 
10.5 | 
120.8 | 
25360 |

3×400 | 
10.5 | 
127.8 | 
31580 |

*Compacted conductor
 
 
10,Product Data Of Cable


Nominal cross-sectional area of conductor(mm²) | 
Max.D.C resistance of conductor at 20ºC(Ω/km) | 
Max.short circuit current of conductor at 90ºC |

Copper conductor | 
Copper conductor |

25 | 
0.727 | 
3.69 |

35 | 
0.524 | 
5.15 |

50 | 
0.387 | 
7.31 |

70 | 
0.268 | 
10.2 |

95 | 
0.193 | 
13.8 |

120 | 
0.153 | 
17.4 |

150 | 
0.124 | 
21.7 |

185 | 
0.0991 | 
26.7 |

240 | 
0.0754 | 
34.6 |

300 | 
0.0601 | 
43.1 |

400 | 
0.0470 | 
57.4 |

500 | 
0.0366 | 
71.7 |

630 | 
0.0283 | 
88.8 |


11,Voltage test and partial discharge test


No. | 
Test items | 
Rated Voltage KV |

26/35 |

1 | 
Power frency A.C.Voltage test (KV/5min) | 
91(65)* |

2 | 
Power frency A.C.Voltage test for 4 hours (KV) | 
104 |

3 | 
Impluse voltage test(KV) | 
250 |

4 | 
Partial discharge test maximum discharge at 1.73Uo pc | 
5 |

The power-frequency voltage test of cables for rated voltage 21/35KV shall be done upon request according to 2.5Uo×30min or 3.5Uo×50min. |


12,Capacitance of cable(reference value)


Nominal cross-sectional area of conductor(mm²) | 
Rated Voltage KV |

26/35 |

Capacitance/phase μF/km |

25 | 
0.0992 |

35 | 
0.1061 |

50 | 
0.1150 |

70 | 
0.1263 |

95 | 
0.1368 |

120 | 
0.1460 |

150 | 
0.1563 |

185 | 
0.1665 |

240 | 
0.1805 |

300 | 
0.1945 |

400 | 
0.2146 |

500 | 
0.2321 |

630 | 
0.2533 |



13,Inductance of cable


Nominal cross-sectional area of conductor(mm²) | 
Rated Voltage KV |

26/35 |

Capacitance/phase μF/km |

1x50 | 
0.6751 |

1x70 | 
0.6467 |

1x95 | 
0.6279 |

1x120 | 
0.6118 |

1x150 | 
0.5959 |

1x185 | 
0.5839 |

1x240 | 
0.5677 |

1x300 | 
0.5540 |

1x400 | 
0.5393 |

1x500 | 
0.5272 |

1x630 | 
0.5161 |

3x50 | 
0.6979 |

3x70 | 
0.4427 |

3x95 | 
0.4208 |

3x120 | 
0.4019 |

3x150 | 
0.3862 |

3x185 | 
0.3737 |

3x240 | 
0.3611 |

3x300 | 
0.3485 |

3x400 | 
0.3266 |

 
 
14,Short circuit current of mechanic-screen


Nominal cross-sectional area of conductor(mm²) | 
Rated Voltage KV |

26/35 |

Short circuit current |

1x50 | 
1288 |

1x70 | 
1286 |

1x95 | 
1283 |

1x120 | 
1282 |

1x150 | 
1282 |

1x185 | 
1279 |

1x240 | 
1278 |

1x300 | 
1277 |

1x400 | 
1274 |

1x500 | 
1273 |

1x630 | 
1270 |

3x50 | 
3031 |

3x70 | 
3031 |

3x95 | 
3031 |

3x120 | 
3031 |

3x150 | 
3031 |

3x185 | 
3031 |

3x240 | 
3031 |

3x300 | 
3031 |

 
 
 
15,Current carrying capacity of cable
Copper conductor XLPE insulated power cable for rated voltage 3.6/6~12/20KV


Copper Conductor | 
Nominal Cross sectional area of conductor mm2 | 
In the air | 
In the ground |

Air temperature:40ºC | 
Air temperature:25ºC |

Single Core | 
Three Core | 
Single Core | 
Three Core |


 | 
 | 

 | 
 |

50 | 
220 | 
245 | 
185 | 
215 | 
225 | 
200 |

70 | 
270 | 
305 | 
230 | 
265 | 
275 | 
250 |

95 | 
330 | 
370 | 
280 | 
315 | 
330 | 
300 |

120 | 
375 | 
425 | 
310 | 
360 | 
375 | 
330 |

150 | 
425 | 
485 | 
260 | 
400 | 
420 | 
380 |

185 | 
485 | 
555 | 
400 | 
455 | 
475 | 
425 |

240 | 
560 | 
650 | 
470 | 
525 | 
555 | 
490 |

300 | 
650 | 
745 | 
540 | 
595 | 
630 | 
555 |

400 | 
760 | 
870 | 
610 | 
680 | 
720 | 
625 |

500 | 
875 | 
1000 | 
- | 
775 | 
825 | 
- |

630 | 
1000 | 
1160 | 
- | 
875 | 
940 | 
- |


16,Installation and Operation Condition of Cable
Max.Operation temperature of conductor--------------------------90ºC
Ambient air temperature------------------------------------------------ 40ºC.
Soil temperature---------------------------------------------------------25ºC.
Soil thermal resitivity----------------------------------------------------1.0ºCm/w
Buried depth----------------------------------------------------------------0.8m
Single-Circuit only
Single-core cable is installed in parallel.Adjacent space is equivalent to the diameter of the cable.
Correction factors of current carrying for different soil temperature


Soil temperature(ºC) | 
15 | 
20 | 
25 | 
30 | 
35 | 
40 | 
45 |

Rating factor | 
1.09 | 
1.04 | 
1.0 | 
0.96 | 
0.92 | 
0.87 | 
0.83 |

Correction factors of current carrying for different thermal temperature


Rating factors for soil Thermal resistivityºC.m/w | 
1.0 | 
1.2 | 
1.5 | 
2.0 | 
2.5 | 
3.0 | 
3.5 |

Three cores | 
1.0 | 
0.943 | 
0.877 | 
0.792 | 
0.736 | 
0.675 | 
0.641 |

Single core | 
1.0 | 
0.934 | 
0.850 | 
0.748 | 
0.692 | 
0.635 | 
0.598 |

Correction factors of current carrying for different air temperature


Air temperature(ºC) | 
20 | 
25 | 
30 | 
35 | 
40 | 
45 | 
50 |

Correction factor | 
1.18 | 
1.14 | 
1.10 | 
1.05 | 
1.0 | 
0.95 | 
0.89 |
주소:
Room1116, Floor 11, Hongxing Jiuzhou International Plaza, Xincheng Road, Yixing, Wuxi, Jiangsu, China
사업 유형:
제조사/공장, 무역 회사
사업 범위:
서비스, 전기전자, 화학공업
경영시스템 인증:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001
회사소개:
2014년에 설립되어 30년 이상 케이블에서 일해 온 경험을 바탕으로 한 Lonheo는 공동 운영 공장의 뛰어난 명성을 바탕으로 합니다. 우리가 하는 모든 일은 세계 최고의 케이블 계약자로 만드는 것입니다.
Lonheo는 시너지 효과를 내고 모든 파트너의 리소스를 통합하여 오늘날의 경쟁적인 비즈니스 환경에서 노력할 수 있습니다. 이렇게 하면 Lonheo는 운영 및 재정적으로 강력한 상태를 유지할 수 있습니다.
이러한 전략적 파트너십을 통해 Lonheo는 고객이 목표를 달성하고 더 많은 부가 가치 서비스를 제공할 수 있도록 지원할 수 있습니다.
우리 회사는 케이블 및 와이어 보충과 폐수 처리 화학물질에 초점을 맞추고 있습니다.
당사 기능 제품:
===== 전원 케이블===
= 초고전압, 전원 케이블, 고전압 전원 케이블, 저전압 전원 케이블, LSZH(저연무 제로 할로겐) 케이블, XLPE 케이블, AAC(알루미늄 합금 도체) 전원 케이블, 장갑 케이블, SWA(강철 와이어 장갑차) 케이블
전원 케이블은 주로 전력 산업 및 일반 산업에서 전력 전송 및 분배 시스템에 사용됩니다.
== 전기 장비의 와이어 및 케이블 ==
= 고무 절연 케이블, 광산업, 천공 및 터널링 케이블, 선박 케이블, 나일론 피복 와이어, 플라스틱 절연 제어 케이블
전기 장비 케이블은 주로 전기를 공급하고 분배하는 데 사용됩니다.
=== 공중 케이블 ==
= 공중 번들형 케이블, 구리 유선 와이어, 알루미늄 도체 강철 보강(ACSR) 와이어, 알루미늄 합금 도체(AAC), 알루미늄 유선 도체(AAC)
이 케이블은 주로 송전 및 배전용 오버헤드 전선으로 사용됩니다.
=== 특수 케이블 및 와이어 ==
= 내화성 케이블, 고온방지 케이블, 내연 케이블/흰개미트 방지 케이블, 방수 케이블, 친환경 직류 케이블, 지하철용 중전압 및 경량, 풍력 에너지 케이블, 1E 등급 핵 케이블, 에너지 효율적인 ACSR, UHV 지원 및 오버헤드 와이어 확장 0.6/1KV용 유연한 방화 케이블.