기본 정보
Type
Cabinet Air Conditioner
Air Tube Material
Galvanized Sheet
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Application Fields
Mechanical Engineering
운송 패키지
Wooden Case Packing
원산지
Dongguan, Guangdong, China
제품 설명
Nagoya KC-40 Commercial Ceiling Cold Water Air Cabinet Conditioner For Printing
FAQ
What is your product range?
Main products: water chiller, central air conditioner and related refrigeration equipment.
Are you manufacturer?
Yes, we have own factory with 30 years experience of air conditioner and refrigeration equipment.
How can we pay for?
1. 30% advanced payment, 70% balance payment before shipment normally, and it is negotiable.
2. We accept T/T, Western Union, L/C, and PayPal etc.
3. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
How many days will the products are finished?
1. 10-15 days for small quantity making (like 1-3sets).
2. 20-30 days about the mass products production time, it is up to the quantity.
What are the methods of shipping and price term?
1. We quote FOB Shenzhen normally after clients' enquiry.
2. And we quote CFR and CIF term once got client's details.
3. As it is big volume and heavy items, exporting shipment is by Sea normally.
What competitive advantages do you have?
1. Competitive price
2. Good after-sale service
3. Fast delivery time
4. High quality control
5. Material is made of 100% recycle material
6. Customized technical request, size, design and packing is welcomed
7. Provide one-step service from design, produce to quality control, sale and shipping
what can we benefit from you?
1. We provide OEM and ODM service
2. 100% high quality for every customer
3. Good after-sale service for customer
4. Wholesale price for regular customer
what do you have to ensure that what you said is right?
1. Full set of equipment ensure each process of product be finished. Such as punching machine, bending machine, machining machine and welding machine. And also coating, assembling, testing and packing.
2. First class of salesman to service for every client's demands.
3. Excellent R&D team waiting for clients, if you provide information and request.
4. Highly efficient management systems and quality assurance departments.
What information should i let you know once i want to make an inquiry?
1. The items name such as water chiller, air conditioner etc.
2. What's the use for? Like: for cool down air or machines?
3. Where the equipment should be used? Like: Country and city, factory or others?
4. What about the temperature and humidity request?
5. How many square meter of the space?
6. How many sets you need?
7. What's your seaport or items destination?
Ceiling/Floor Cold Water Air Cabinet |
model | K(X)C-25 | K(X)C-40 | K(X)C-50 | K(X)C-75 | K(X)C-100 | K(X)C-125 | K(X)C-160 | K(X)C-180 | K(X)C-200 |
performance | K(X)F-25 | K(X)F-40 | K(X)F-50 | K(X)F-75 | K(X)F-100 | K(X)F-125 | K(X)F-160 | K(X)F-180 | K(X)F-200 |
nominal air flow | CMH | 2500 | 4000 | 5000 | 7500 | 10000 | 12500 | 16000 | 18000 | 20000 |
cooling capacity (return air) | 4R | kW | 15.6 | 24.8 | 30.3 | 44.4 | 61.1 | 74.4 | 96.8 | 107.8 | 118.4 |
6R | kW | 20.5 | 31.2 | 39.5 | 57.3 | 79.7 | 96.2 | 124 | 139.5 | 152.7 |
cooling capacity (fresh air X) | 4R | kW | 29.4 | 44.5 | 57 | 83.2 | 115 | 139.7 | 179.8 | 202.3 | 222 |
6R | kW | 39.5 | 59.6 | 76.5 | 111.5 | 154.2 | 187.2 | 241 | 271.1 | 297.4 |
heating capacity (return air) | 4R | kW | 23.4 | 37.2 | 45.5 | 66.6 | 91.7 | 111.6 | 145.2 | 161.7 | 177.6 |
6R | kW | 30.8 | 46.8 | 59.3 | 86.0 | 119.6 | 144.3 | 186.0 | 209.3 | 229.1 |
heating capacity (fresh air X) | 4R | kW | 44.1 | 66.8 | 85.5 | 124.8 | 172.5 | 209.6 | 269.7 | 303.5 | 333.0 |
6R | kW | 59.3 | 89.4 | 114.8 | 167.3 | 231.3 | 280.8 | 361.5 | 406.7 | 446.1 |
external static pressure | 4R | Pa | 130 | 130 | 160 | 250 | 280 | 350 | 400 | 430 | 450 |
6R | Pa | 100 | 100 | 130 | 220 | 250 | 320 | 370 | 400 | 420 |
motor power | kW | 0.45 | 0.75 | 1.1 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 5.5 |
power supply | 3PH 380V 50Hz |
noise | dB(A) | ≤56 | ≤62 | ≤64 | ≤68 | ≤70 | ≤72 | ≤73 | ≤73 | ≤73 |
chilled water flow(return air) | 4R | CMH | 2.7 | 4.3 | 5.2 | 7.6 | 10.5 | 12.8 | 16.6 | 18.5 | 20.4 |
6R | CMH | 3.5 | 5.4 | 6.8 | 9.9 | 13.7 | 16.5 | 21.3 | 24.0 | 26.3 |
chilled water flow(fresh air X) | 4R | CMH | 5.1 | 7.7 | 9.8 | 14.3 | 19.8 | 24.0 | 30.9 | 34.8 | 38.2 |
6R | CMH | 6.8 | 10.2 | 13.2 | 19.2 | 26.5 | 32.2 | 41.4 | 46.6 | 51.1 |
water pressure drop.(return air) | 4R | kpa | 16.6 | 11.0 | 10.8 | 15.4 | 18.0 | 17.9 | 9.0 | 9.1 | 9.8 |
6R | kpa | 10.6 | 20.0 | 18.7 | 28.3 | 18.2 | 18.5 | 15.6 | 15.8 | 17.7 |
water pressure drop.(fresh air X) | 4R | kpa | 18.2 | 24.9 | 29.8 | 16.9 | 19.8 | 19.8 | 26.3 | 24.7 | 26.1 |
6R | kpa | 17.5 | 25.1 | 30.6 | 29.1 | 19.5 | 19.1 | 25.8 | 25.3 | 26.7 |
Dia. Of pipe (return air) | 4R | in | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 2-1/2 | 3 |
6R | in | 1-1/4 | 1-1/2 | 1-1/2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 |
Dia. Of pipe (fresh air X) | 4R | in | 1-1/2 | 2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 3 | 4 |
6R | in | 1-1/2 | 2 | 2-1/2 | 2-1/2 | 3 | 3 | 4 | 4 | 4 |
K(X)C dimension | width | mm | 1000 | 1200 | 1200 | 1700 | 1840 | 1840 | 2150 | 2150 | 2150 |
depth | mm | 1000 | 1150 | 1150 | 1150 | 1150 | 1150 | 1250 | 1250 | 1250 |
height | mm | 560 | 740 | 740 | 740 | 920 | 1063 | 1160 | 1280 | 1320 |
K(X)F dimension | width | mm | 1000 | 1200 | 1200 | 1700 | 1840 | 1840 | 2150 | 2150 | 2150 |
depth | mm | 600 | 600 | 600 | 600 | 820 | 820 | 1050 | 1050 | 1050 |
height | mm | 1350 | 1450 | 1450 | 1450 | 1680 | 1800 | 2000 | 2100 | 2200 |
K(X)C net weight (about) | 4R | kg | 100 | 120 | 150 | 210 | 240 | 270 | 360 | 380 | 400 |
6R | kg | 110 | 130 | 180 | 230 | 270 | 310 | 400 | 420 | 450 |
K(X)F net weight (about) | 4R | kg | 110 | 140 | 160 | 280 | 300 | 380 | 430 | 460 | 490 |
6R | kg | 120 | 150 | 190 | 300 | 350 | 430 | 480 | 520 | 540 |
Note: The data is measured in the next standard condition: |
1. cool: return air: 27ºC/19.5ºC, fresh air: 34ºC/28ºC, inlet/outlet water temperature: 7ºC/12ºC. |
2. warm: return air: inlet air 7ºC, fresh air: inlet air 21ºC, inlet/outlet water temperature: 60ºC/50ºC. |
| | | | | | | | | | | |
| | | | | | | | | | | |
| | | | | | | | | | | |
주소:
Hadi Industrial Area, Nancheng, Dongguan, Guangdong, China
사업 유형:
제조사/공장, 무역 회사
사업 범위:
공업 설비와 부품, 전기전자, 제조 가공 기계
경영시스템 인증:
ISO 9001
주요 상품:
중앙 에어컨, 중앙 에어컨, 에어컨, 에어컨, 에어컨, 워터 냉각기, 수랭식 냉각기, 냉각기, 상업 중심 에어컨, 산업용 중앙 에어컨, 공랭식 냉각기
회사소개:
1977년 나고야 에어컨디셔션 및 냉동 주식회사를 홍콩에서 설립했으며 1991년 광둥성의 둥관에 공장을 세웠습니다. 이 회사는 중앙 냉난방 및 보조 장비의 전문적이고 현대적인 제조업체로 개발되었으며 연간 수용 인원 8000대 이상이며, 중국에서 잘 판매되고 있으며 해저 시장으로 수출되고 있습니다.
나고야는 캐나다, 홍콩 및 대만의 주주들이 공동 설립한 합작 투자사이며 ISO9001 국제 품질 인증 인증을 받았습니다. ISO9001 품질 보증 시스템을 기반으로 Nagoya는 제품 품질 및 서비스 품질을 보장하기 위한 완벽한 관리 시스템을 구축했으며, 각 부서는 보다 명확한 업무 분과에서 서로 조율하고 고객의 요구에 보다 신속하게 대응하기 위해 공동 노력을 하고 있습니다. 보다 효과적인 서비스를 제공하여 그 효율성을 지속적으로 개선합니다. 나고야의 관점에서 볼 때 현재 시장 경쟁은 인재 경쟁에 달려 있으며, 회사는 "사람 중심의 가치 기반"이라는 인재 전략을 구현하고 교육 배경이 아닌 근력 강화에 더 주의를 기울여야 합니다. 사람 중심의 기업 문화 하에서 Nagoya는 활기차고, 통합적이며, 도전적이고, 혁신적인 팀을 만들었으며, 제품의 특징으로는 안정적인 성능, 뛰어난 품질, 그리고 1등급 애프터세일즈 서비스가 있습니다. 따라서 "나고야" 제품은 빠르게 수용 가능하며 많은 중국 및 외국 기업이 선호하는 브랜드로 모든 부문에서 높은 평가를 받고 있습니다.
철저하게 사업을 하고, 사회의 자원을 활용하고, 사회에 기여하며, 따라서 건성하고 책임감 있는 방식으로 성장하고 발전합니다. 나고야는 사회의 요구를 충족하기 위해 새로운 제품의 혁신과 개발에 참여하고 있으며, 이는 수십 년 동안 회사의 발전입니다.
회사는 항상 "품질 우선, 고객 중심"이라는 정신을 고수하고 성실하게 비즈니스를 수행했으며, 고품질의 제품과 완벽한 판매 전 및 판매 후 서비스를 제공하기 위해 모든 노력을 기울였습니다. 따라서 완벽한 Acme에 도달하고 고객의 지원을 다시 지불하면 됩니다.