기본 정보
모델 번호.
3HP/5HP/8HP/10HP/15HP/20HP/25HP
제품 설명
Electrophoresis special refrigeration equipment (1) chiller transportation moving should make the necessary protective measures, rainproof bull. (2) machine in handling process, loading and unloading car should be light, avoid touch attack. Second, the machine is installed (1) the machine should be installed in the well ventilated, dry, no air pollution, and environmental temperature, no more than 45 ° indoor, installation position to balance.(2) the in-out water chillers, circulation cooling water pipes, matching correctly, reasonable design, reasonable design connection not leak.(3) from surrounding walls refrigerating not less than 45CM blockage. Third, the power connector (1) the machine adopts three-phase four-wire, power, (R, S, T) 380V power lines (N), and meet up neutral grounding wire connection "correct".(2) the power generator voltage: 380V ± 10%. Electricity frequently rate: isolator ± 2%(3) power supply voltage fluctuation, cannot start the machine transducer, such as forced open machines to bring the machine, the company does not damage the responsibility.(4) control of the machine, the electrical appliances chain circuit arbitrarily change, it shall be the client needs to change in the company, the company, or until after checking contents alter line again, otherwise, the company inform the client does not bear the consequences of after the changes. Four, the machine operation (1) before starting around carefully check whether there is abnormal, wire connection, whether it is right, tighten conduit installation is correct, the voltage is normal.(2) open valve, check automatic water chillers tank has been filled with water (whether to check the cooling tower, water pump, water condenser circulating system until the water full without water or water do not run).(3) turn on the power switch, watch the lights on the panel, and display, pump has a thermometer on the job, and the thermometer, little also host to delay 4 minutes on it again. Five, temperature adjustment Operational guidelinesThe lights on the thermometer from top to bottom of the table meaning function: Bright lights flashingTemperature limit set limit temperatureLower temperature limit temperature settingemptyRefrigeration compressor boot is protected. Delay How to set upper temperature?At the same time in two key, enter temperature limit state, digital display Settings display temperature to limit temperature (" thickening 0.1 ° c ", "button 0.1 ° c," button to reduce down more than 0.5 seconds is quick put reduced). After the completion of the upper temperature setting, and according to the key to store the data. According to the same methods set temperature limit. Note that "> upper limit controller this rule.Note: 1, in the status, if not connected 5 seconds, automatic exit status.2, the heart must exit status to ensure that data will be stored. If the electricity, didn't quit before setting value may not be preserved.* basic working principletemperature control Temperature control according to the "upper" and "lower temperature, temperature" two parameters hypotheses "limit for 20 degrees Celsius temperature", "lower temperature" for 18 degrees Celsius, when the temperature control of temperature probe on perceived than 20 ° c j-t until the temperature is below 18 degrees temperature control, will stop refrigeration in 18 degrees - 20 ° c.When the extended compressor bootThere is a "controller", when the timer compressor stop timing starts when stop compressor, the first check before starting compressor, if has the timer with four minutes to start compressor, if dissatisfied with four minutes as four minutes is restarted. This can be restarted after stopping guarantee interval 4 minutes, prevent frequently damage compressor.Another controller of electricity within four minutes, just won't start compressor, this call again in electricity situation also can protect the compressor. (note: compressor in the time when extended protection on the above assumptions, adjustable Settings for four minutes). 6 and failure analysis, and simple questions processing method (1) panel indicatorName state processing method Phase failureLight (1) the power supply voltage is not normal, or the power of a photograph investigations(2) the power R, S, T sequence of two lines, exchange of position System fault not bright says input circuit is normal Bright, ventilated and undesirable heat that should check whether the machine is water-cooled (the obstacles to check, cooling tower, water pump, not the condenser circulating system is normal operation thereof, according to the problems after) inside the machine pressure switch (two little red dot) reset. Host system fault not light Light (1) from ac contactor to check whether the power cord connecting main compressor normal (2) host has damaged (please check technicians specialized refrigeration), Pump failureLight (1) for a long time when the pump's live (for supplemental pump start-up),(2) host water pump has been damaged, replace or pump. A host running on normal workDon't light didn't boot, or control in delay Note: if the equipment failure, please press the check cannot be excluded, if the company or professional please contact: no refrigeration technician experience cut from further loss. Seven, the daily maintenance and maintenance (1) every time before starting the check whether there is abnormal things around letter voltage, water pump, water pipe flow, whether there is water, cooling water circulation outside is normal or not.(2) chiller every operation period, usually two to three months, according to the heat transfer air-filled type to clean, water-cooled to clean with clear water cooling towers.(3) annually to do a big maintenance, do a machine maintenance and cleaning up.(4) advice in a professional technicians with refrigeration equipment maintenance etc.Electrophoresis special refrigeration equipment A machine (1) chiller transportation moving should make the necessary protective measures, rainproof bull. (2) machine in handling process, loading and unloading car should be light, avoid touch attack. Second, the machine is installed (1) the machine should be installed in the well ventilated, dry, no air pollution, and environmental temperature, no more than 45 ° indoor, installation position to balance.(2) the in-out water chillers, circulation cooling water pipes, matching correctly, reasonable design, reasonable design connection not leak.(3) from surrounding walls refrigerating not less than 45CM blockage. Third, the power connector (1) the machine adopts three-phase four-wire, power, (R, S, T) 380V power lines (N), and meet up neutral grounding wire connection "correct".(2) the power generator voltage: 380V ± 10%. Electricity frequently rate: isolator ± 2%(3) power supply voltage fluctuation, cannot start the machine transducer, such as forced open machines to bring the machine, the company does not damage the responsibility.(4) control of the machine, the electrical appliances chain circuit arbitrarily change, it shall be the client needs to change in the company, the company, or until after checking contents alter line again, otherwise, the company inform the client does not bear the consequences of after the changes. Four, the machine operation (1) before starting around carefully check whether there is abnormal, wire connection, whether it is right, tighten conduit installation is correct, the voltage is normal.(2) open valve, check automatic water chillers tank has been filled with water (whether to check the cooling tower, water pump, water condenser circulating system until the water full without water or water do not run).(3) turn on the power switch, watch the lights on the panel, and display, pump has a thermometer on the job, and the thermometer, little also host to delay 4 minutes on it again. Five, temperature adjustment Operational guidelinesThe lights on the thermometer from top to bottom of the table meaning function: Bright lights flashingTemperature limit set limit temperatureLower temperature limit temperature settingemptyRefrigeration compressor boot is protected. Delay How to set upper temperature?At the same time in two key, enter temperature limit state, digital display Settings display temperature to limit temperature (" thickening 0.1 ° c ", "button 0.1 ° c," button to reduce down more than 0.5 seconds is quick put reduced). After the completion of the upper temperature setting, and according to the key to store the data. According to the same methods set temperature limit. Note that "> upper limit controller this rule.Note: 1, in the status, if not connected 5 seconds, automatic exit status.2, the heart must exit status to ensure that data will be stored. If the electricity, didn't quit before setting value may not be preserved.* basic working principletemperature control Temperature control according to the "upper" and "lower temperature, temperature" two parameters hypotheses "limit for 20 degrees Celsius temperature", "lower temperature" for 18 degrees Celsius, when the temperature control of temperature probe on perceived than 20 ° c j-t until the temperature is below 18 degrees temperature control, will stop refrigeration in 18 degrees - 20 ° c.When the extended compressor bootThere is a "controller", when the timer compressor stop timing starts when stop compressor, the first check before starting compressor, if has the timer with four minutes to start compressor, if dissatisfied with four minutes as four minutes is restarted. This can be restarted after stopping guarantee interval 4 minutes, prevent frequently damage compressor.Another controller of electricity within four minutes, just won't start compressor, this call again in electricity situation also can protect the compressor. (note: compressor in the time when extended protection on the above assumptions, adjustable Settings for four minutes). 6 and failure analysis, and simple questions processing method (1) panel indicatorName state processing method Phase failureLight (1) the power supply voltage is not normal, or the power of a photograph investigations(2) the power R, S, T sequence of two lines, exchange of position System fault not bright says input circuit is normal Bright, ventilated and undesirable heat that should check whether the machine is water-cooled (the obstacles to check, cooling tower, water pump, not the condenser circulating system is normal operation thereof, according to the problems after) inside the machine pressure switch (two little red dot) reset. Host system fault not light Light (1) from ac contactor to check whether the power cord connecting main compressor normal (2) host has damaged (please check technicians specialized refrigeration), Pump failureLight (1) for a long time when the pump's live (for supplemental pump start-up),(2) host water pump has been damaged, replace or pump. A host running on normal workDon't light didn't boot, or control in delay Note: if the equipment failure, please press the check cannot be excluded, if the company or professional please contact: no refrigeration technician experience cut from further loss. Seven, the daily maintenance and maintenance (1) every time before starting the check whether there is abnormal things around letter voltage, water pump, water pipe flow, whether there is water, cooling water circulation outside is normal or not.(2) chiller every operation period, usually two to three months, according to the heat transfer air-filled type to clean, water-cooled to clean with clear water cooling towers.(3) annually to do a big maintenance, do a machine maintenance and cleaning up.(4) advice in a professional technicians with refrigeration equipment maintenance etc.
주소:
Building 3, Furong Xinda Technology Park, Shajing Town, Baoan District, Shenzhen
사업 유형:
제조사/공장
사업 범위:
공업 설비와 부품, 보디빌딩과 오락 여가, 자동차와 오토바이와 액세서리, 장난감, 전기전자, 제조 가공 기계, 화학공업
경영시스템 인증:
ISO 9001
회사소개:
Shenzhen Yuehuiwuang Automation Equipment Co., Ltd.는 전기 영동 코팅 전문 제조사로, 10년 이상 전기 영동 코팅 제조 시 특히 적용되었으며, 전기영동 코팅 분야에서 최고의 선두 주자가 되었으며 가장 뛰어난 전기영동 코팅 장비 기업 중 하나입니다. 이 회사는 5억 명의 자본에 등록했고 해외에서 장기 서비스를 제공하는 70명 이상의 전문가를 보유하고 있습니다. 우리 제품은 한국, 베트남, 러시아, 그리고 10개 이상의 국가와 지역에 유통됩니다. YueHuiHuang은 ISO9001에 부합하는 최고급 제품, 품질 및 서비스를 제공합니다. 전기영동 장비 모델 선택, 계획, 설계, 설치, 디버깅, 광학 전기영동 코팅, 교정 및 교육 기술
저희 회사의 장비 제조 대장은 광둥성에 있으며 그림 제조는 저장성에 있습니다. 이 회사는 완벽한 애프터 네트워크 시스템을 갖추고 있으며 광저우 파누, 산둥 웨이팡, 랴오닝 선양, 저장성 원저우, 헨란 정저우 등 고객 집약적 지역에 있습니다. 루오양, 산시성 시안, 허베이 시자강신일, 후난 소둥, 쓰촨 청두, 고객의 문제를 단시간에 해결하기 위해 애프터세일즈 서비스 포인트 또는 하위 브랜치 커밋이 제공됩니다. 현재, 우리 회사는 중국에서만 서비스를 제공할 뿐만 아니라 해외에서도 서비스를 제공하고 있습니다.
우리의 장점: 우리는 다양한 엔지니어링 사례를 경험했고 요약에 따라 고객의 요구에 따라 모든 보조 장비를 지속적으로 개발 및 개선하고 모든 독립 생산을 달성했다. 고객의 장비 사용 과정에서 발생하는 모든 문제를 해결하기 위해 최선을 다하며, 코팅을 직접 제조합니다.
우리의 영역: 오랜 세월 동안 열심히 일하고 연습한 후 톱 블레이드 전기영동 및 휠 얼라인먼트에 중요한 기술 혁신을 이룩했습니다. 우리가 계획하고 설계하는 장비, 첨단 전기영동을 통한 톱 블레이드 및 허브 판자링 등은 국내외에서 고객의 칭찬을 받습니다. 자동차 부품, 농업기계, 세발자전거, 경트럭, 특수 차량 도어 및 창문 장식, 모터 및 기타 하드웨어 액세서리 산업에서 동시에 뛰어난 성능을 발휘하며 해당 산업 벤치마킹 기업에서 많은 성공 사례를 보유하고 있습니다.
우리의 아이디어: 우리는 제품의 품질과 혁신을 위해 노력하고, 끊임없이 새로운 첨단 과학 및 기술을 도입하고, 회사 관리를 강화하고, 직원 교육을 개선하고, 품질 관리 데이터, 완벽한 설계 개념, 고품질 사전 판매, 판매, 애프터세일즈 서비스 회사는 "과학 및 기술 혁신, 우수성, 지속 가능한 개발, 선의의 서비스"라는 비즈니스 철학을 지지합니다.