WE do HUAYI brand name item,mainly offering Digital Multimeter,Infrared Thermometer,Process Calibrator,Digital Clamp Meter,Laser/Ultrasonic Distance Meter,Digital Earth Resistance Tester,Digital Insulation Resistance Tester,Digital PH/Anemometer,Lux Meter,Gas Analyzer,Voltage Detector and so on,and selling Fluke items with similar products as above.
Also Agent for Endress Hauser,Offering Digital pH Sensor Orbisint Electrode / Pressure Transmitter / Liquid Level Limit Switch Liquiphant / Prosonic T Ultrasonic Level Meter / Temperature Head Transmitter iTEMP PCP...
Selling thermal Image Camera from Flir company.
Pls contact me freely if there any interested in we other items.
MS8236 DIGTAL METER USB
General Technical Specifications
l Environment condition of using:
600V CAT.IV and 1000V CAT.III
Pollution level: 2
Altitude < 2000m
Working environment temperature and humidity: 0~40°C (<80% RH, <10°C non condensing).
Storage environment temperature and humidity: -10~60°C (<70% RH, remove the battery).
l Temperature coefficient: 0.1´ accuracy/°C (<18°C or >28°C).
l MAX. Voltage between terminals and earth ground:1000V DC or 750V AC RMS
l Fuse protection: mA: fuse F600mA/1000V fast speed fuse; 10A shift: F10A/1000V fast speed fuse
l Sampling rate: about 3 times/second.
l Display: 6000 counter readout. Automatically display the unit symbols according to the shift of the measurement function.
l Over range indication: it displays "OL".
l Low battery indication: when the battery voltage is lower than the normal working voltage, "" will be displayed.
l Input polarity indication: automatically display "-".
l Power requirement: 4 x 1.5V AA batteries.
l Dimension: 204(L) ´94(W) ´ 57(H) mm.
l Weight: about 410g (including batteries).
Accuracy Specifications
The accuracy applies within one year after the calibration.
Reference condition: the environment temperature 18°C to 28°C, the relative humidity is no more than 80%, accuracy: ±(% reading + word).
DC Voltage
Range | Resolution | Accuracy | Input impedance: 10MΩ(60/600mV range is 1011Ω) Overload protection: 1000V DC or 750V AC (RMS) Maximum input voltage: 1000V DC Note: Measure in mV (60/600mV) voltage, input impedance is as high as 1011Ω, and weak signal of measurement does not weaken, so the measurement precision is high. But in the circumstance that the probe is open circuit it will display numbers, which is normal, as long as in short circuit the probe will return to zero or the probe is inserted to the measured point, the reading will stabilize. |
60mV | 0.01mV | ±(0.7% reading+2) |
600mV | 0.1mV |
6V | 1mV |
60V | 10mV |
600V | 100mV |
1000V | 1V |
AC Voltage
Range | Resolution | Accuracy | Input impedance: 10MΩ(60/600mV range is 1011Ω) Overload protection: 1000V DC or 750V AC (RMS) Maximum input voltage: 750V AC (RMS) Frequency range: 10Hz ~ 1kHz; response: true RMS Note: Measure in mV (60/600mV) voltage, input impedance is as high as 1011Ω, and weak signal of measurement does not weaken, so the measurement precision is high. But in the circumstance that the probe is open circuit it will display numbers, which is normal, as long as in short circuit the probe will return to zero or the probe is inserted to the measured point, the reading will stabilize. |
60mV | 0.01mV | ±(0.8% reading+3) |
600mV | 0.1mV |
6V | 1mV |
60V | 10mV |
600V | 100mV |
750V | 1V | ±(1.0% reading +3) |
DC Current
Range | Resolution | Accuracy | Overload protection: mA/mA range:600mA/1000V fuse (fast speed fuse) 10A range: 10A/1000V fuse (fast speed fuse) Maximum input current: mA socket: 600mA 10A socket: 10A When measuring large current, continuous measurement should be not longer than 15 seconds, after measurement the instrument should be cooled down after twice of the measurement time, and then enter small current measurement. |
600mA | 0.1mA | ±(1.2% reading +3) |
6000mA | 1mA |
60mA | 10mA |
600mA | 100mA |
6A | 1mA | ±(2.0% reading +10) |
10A | 10mA |
AC Current
Range | Resolution | Accuracy | Overload protection: mA/mA range: 600mA/1000V fuse (fast speed fuse) 10A range: 10A/1000V fuse (fast speed fuse) Maximum input current: mA socket: 600mA 10A socket: 10A Frequency range: 10Hz~1kHz Response: true RMS When measuring large current, continuous measurement should be no longer than 15 seconds, after measurement the instrument should be cooled down after twice of the measurement time, then enter small current measurement. |
600mA | 0.1mA | ±(1.5% reading +3) |
6000mA | 1mA |
60mA | 10mA |
600mA | 100mA |
6A | 1mA | ±(3.0% reading +10) |
10A | 10mA |
Resistance
Range | Resolution | Accuracy | Open circuit voltage: about 0.25V Overload protection: 1000V DC or 750V AC (RMS) |
600Ω | 0.1Ω | ±(1.2% reading+5) |
6kΩ | 1Ω |
60kΩ | 10Ω |
600kΩ | 100Ω |
6MΩ | 1kΩ |
60MΩ | 10kΩ | ±(2.0% reading+5) |
Capacitance
Range | Resolution | Accuracy | Overload protection: 1000V DC or 750V AC (RMS) Note: Parameter does not include error caused by the capacitor and capacitor substrate of the probe (in 100nF range may be up to a few nF). The user can use the relative value measurement function to reduce the error. |
10nF | 0.001nF | ±(3.0% reading+3) |
100nF | 0.01nF |
1000nF | 0.1nF |
10mF | 0.001mF |
100mF | 0.01mF |
1000mF | 0.1mF |
10mF | 0.001mF |
Frequency and duty ratio
Range | Resolution | Accuracy | Through shift of Hz: 1)Measurement range: 0 ~ 10MHz 2)Input voltage range: 0.2~10V AC ( the input voltage should be increased with the increase of the measured frequency) 3)Overload protection: 1000V DC or 750V AC (RMS) Through shift V: 1)Measurement range:0 ~ 100kHz 2)Input voltage range: 0.5~750V AC ( the input voltage should be increased with the increase of the measured frequency) 3)Maximum input voltage: 1000V DC or 750V AC (RMS) Through shifts of mA, mA, A: 1)Measurement range:0 ~ 100kHz 2)Input signal range: ≥ ¼ range ( the input current should be increased with the increase of the measured frequency) 3) Input protection: mA, mA range: F600mA/1000V ultra-speed fuse; 10A range: F10A/1000V ultra-speed fuse |
10Hz | 0.001Hz | ±(1.0% reading + 5) |
100Hz | 0.01Hz |
1000Hz | 0.1Hz |
10kHz | 0.001kHz |
100kHz | 0.01kHz |
1000kHz | 0.1kHz |
10MHz | 0.001MHz |
1~99% | 0.1% | ± 3.0% |
Note:
Compared with the range of measurement by using the "Hz" function of voltage and current shifts, using shift "Hz" to measure the frequency has larger range and higher sensitivity.
Diode Test
Range | Resolution | Accuracy | Forward DC current is about 1mA Reverse DC voltage is about 1.5V Overload protection:1000V DC or 750V AC (RMS) |
| 1mV | It displays the approximate forward voltage value of the diode. |
Connectivity Test
Range | Function | Open circuit voltage is about 0.5V Overload protection:1000V DC or 750V AC (RMS) |
| The resistance of the measured circuit is less than 50W, the buzzer contained in the instrument will sound. |
Temperature
Range | Resolution | Accuracy | Overload protection: 1000V DC or 750V AC (RMS) |
ºC | 1ºC | -20ºC~ 0ºC | ± 5.0% reading or ± 3ºC |
0ºC ~ 400ºC | ± 1.0% reading or ± 2ºC |
400ºC~1000ºC | ± 2.0% reading |
ºF | 1ºF | -4ºF~32ºF | ± 5.0% reading or ± 6ºF |
32ºF~752ºF | ± 1.0% reading or ± 4ºF |
752ºF~1832ºF | ± 2.0% reading |
주소:
Zhenyecheng Fushi 3a of 1d8 Building, Henggang Street, Longgang District, Shenzhen, Guangdong, China
사업 유형:
제조사/공장, 무역 회사
사업 범위:
측정 기계
회사소개:
Shenzhen Amerson Flying Co., Ltd는 모든 종류의 계측기 판매를 전문으로 하는 새로운 설립 회사입니다.
중국 주요 전기 도시 광둥 성 선전(Shenzhen)에 위치한 이 호텔은 생산, 마케팅 및 R&D를 담당하는 전문 팀을 보유하고 있습니다 우리 제품 외에도, 우리는 OEM 서비스를 제공하고 사용자 지정 주문을 받습니다. 우리는 이미 전 세계의 많은 유명한 회사를 위한 디자인을 개발하였습니다.
Shenzhen Amerson Flying Co., Ltd.는 공정 칼리브레이터, 적외선 온도계, 디지털 멀티미터, 디지털 클램프 미터, 파워 클램프 미터, 접지 저항 테스터, 절연 테스터, 환경 측정기, 전기 테스터, 네트워크 케이블 테스터 등
당사의 제품은 전 세계, 특히 유럽, 북미, 남미, 남아시아 등 여러 국가와 지역으로 수출되었습니다. 우리 제품은 고객 사이에서 좋은 평판을 얻고 있습니다.
현재 상호 이익을 바탕으로 해상 고객들과의 협력을 더욱 강화하기를 기대하고 있습니다. 당사 제품에 관심이 있다면 언제든지 문의해 주십시오.