기본 정보
원산지
Nanjing Jiangsu, China
제품 설명
WK-2000 Sulfur/Chlorine Analyzer
Model WK-2000Sulfur/Chlorine Analyzer applies microcoulomb analysis principle, and uses Windows Chinese operation platform to display the condition and parameters of the whole process. It also supports the connection with LIMS system to generate the open data format, thus the instrument is suitable for different samples. The analyzer has many characteristics, such as reliable performance, good stability, wide measuring range, fast analysis speed, automatic false peak filtering, automatic calibration, and so on. The instrument is widely used in the product analysis and scientific research of petrochemical, metallurgy, and Colleges and universities, etc.
Standard:
1. SH/T 0253-1992 Total sulfur content determination method in the light petroleum products (Coulometry method)
2. SH/T 0222-1992 Total sulfur content determination method in the Liquefied petroleum gas (LPG) (Coulometry method)
2. GB/T 11061-1997 Total sulfur content determination in the Natural gas--Oxidation microcoulomb method
3. GB/T 632.4-1986 Micro-sulfur content determination in the Organic liquid products_Microcoulomb method
4. GB/T 12688.6-1990 Micro-sulfur content determination in the Styrene for industrial use--Oxidation microcoulomb method
5. GB/T 11141-1989 Micro-sulfur content determination in the light olefins--Oxidation microcoulomb method
6. ASTM D5808 Detect Standard test method of Chlorine in the Aromatic hydrocarbons and related chemicals by microcoulomb method
7. ASTM D5194 Detect test method of trace Chloride in the liquid Aromatic hydrocarbons
8. SY/T7508-1997 Total sulfur content determination in the Liquefied petroleum gas of Oil and gas fields --Oxidation microcoulomb method
9. SH/T1757-2006 Organochlorine determination in Aromatic hydrocarbons for industrial use--Microcoulomb method
10. GB/T 18612-2001Organochlorine content determination in the Crude oil
Specifications:
1. Analytical element: S/Cl
2. Method principle: Coulometry method
3. Execution standard: SH/T 0253
4. Generated current: ± 2mV
5. Electrolytic voltage: ± 30V
6. Bias voltage range: 10 to 400 mV
7. Measurement range: S: 0.1 to 5000mg/L
Cl: 0.2 to 5000mg/L
8. Error of repeatability: X≤ 0.5mg/ L, < 30%
0.5 mg/L < X≤ 1.0 mg/L, < 10%
1.0	mg/L < X≤ 10 mg/L, < 8%
X > 10 mg/L, < 4%
9. Temperature control range: Room temperature to 1100oC
Product characteristics:
1. Long stable time of titration cell (S > 8 hours, Cl > 5hours)
2. Furnace temperature design on the both ends for sample burning more completely
3. Real-time monitor temperature, gas flow and gas pressure in pipelines
4. Optional single point and multi-point calibrations
5. Historical data and graphics playback, which is convenient for comparison analysis
6. Set only one time when reducing the bias voltage
7. Match appropriate sample injector, which can analyze solid, liquid and gaseous samples
8. USB port, which can match different models of computers
9. ACCESS data base, automatically save historical parameters and data
10. Support the connection with LIMS system
주소:
9 Bofu Road, Zhongshan Science Park, Liuhe District, Nanjing, Jiangsu, China
사업 유형:
제조사/공장
사업 범위:
측정 기계
회사소개:
난징 강창 과학용 장비 주식회사는 난징 중산 기술 공원에 위치해 있으며 첨단 기술 기업 중 한 곳에서 R&D, 제조, 판매 및 서비스를 제공합니다. 이 회사는 강력한 기술력, 정교한 검출 수단, 고급 생산 기술, 완벽한 품질 보증 시스템, 전문 연구 개발 및 오일 성분 분석 기기 제조, 환경 수질 분석 기기, 전기화학 분석 기기를 보유하고 있습니다. 석유화학, 환경 모니터링, 의료, 대학, 기타 생산, 교육 및 과학 연구 산업, 국내 주요 성과 지표, 국가 내 제품 및 해외 시장에 수출되는 산업 분야에서 널리 사용되고 있습니다.
WK-2000 시리즈의 회사 독립 연구 개발 및 개발 제품 - 초고감도와 우수한 재현성을 갖춘 총 황 염소 분석기 전해질 세포 안정성은 전 세계 최초로 우리 나라의 마이크로 쿠클로브 방식으로 총 황 총 염소 분석기를 측정할 수 있게 해 줍니다.
이용자 최우수 서비스 아이디어, 기업정신 추구, 정관회사는 국내 및 주요 연구소에 성실히 협조하고, 첨단 제품의 무소속 지적재산권을 개발하며, 고객에게 지침을 제공하기 위해 노력하고 있습니다. 지속적인 혁신을 목표로 하기 위해, 최신 최고의 제품을 지속적으로 개발하십시오.
우리는 끊임없는 노력과 지속적인 혁신을 통해 모든 삶의 요구를 충족하는 보다 발전된 제품과 완벽한 서비스를 제공할 것입니다!