기본 정보
신청
공사, 지하에, 산업의, 발전소, 전기 통신
Sample Free
Certification: ISO9001,AAA Honest Company
제품 설명
Basic Info.
Voltage:Low and Medium Voltage Cable
Insulation Material:XLPE
Current:DC Cable
Application:Underground
Certification:ISO, CE, SABS
Export Markets:Global
Additional Info.
Trademark:JIAPU
Packing:Wooden Drum
Standard:CE SGS SABS
Origin:Henan China
HS Code:8544492100
Production Capacity:100000m /Day
Product Description
Medium Voltage XLPE Insulated Unarmoured Power Cable
Application
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable |
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 |
Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | 6 | 3.4 | 0.1 | 2.1 | 38.7 | 1.3 | 1.75 | 1.2 | 0.727 |
35 | 6.9 | 3.4 | 0.1 | 2.2 | 40.9 | 1.47 | 2.22 | 0.868 | 0.524 |
50 | 8.2 | 3.4 | 0.1 | 2.3 | 43.9 | 1.7 | 2.5 | 0.641 | 0.387 |
70 | 9.7 | 3.4 | 0.1 | 2.4 | 47.3 | 2.02 | 3.25 | 0.443 | 0.268 |
95 | 11.3 | 3.4 | 0.1 | 2.5 | 51 | 2.42 | 4.12 | 0.32 | 0.193 |
120 | 12.8 | 3.4 | 0.1 | 2.6 | 54.4 | 2.79 | 4.95 | 0.253 | 0.153 |
150 | 14.2 | 3.4 | 0.1 | 2.7 | 57.6 | 3.17 | 5.87 | 0.206 | 0.124 |
185 | 15.9 | 3.4 | 0.1 | 2.8 | 61.5 | 3.69 | 7.06 | 0.164 | 0.0991 |
240 | 18.3 | 3.4 | 0.1 | 2.9 | 66.9 | 4.38 | 8.82 | 0.125 | 0.0754 |
300 | 20.4 | 3.4 | 0.1 | 3.1 | 71.8 | 5.11 | 10.68 | 0.1 | 0.0601 |
400 | 23.2 | 3.4 | 0.1 | 3.3 | 78.3 | 6.24 | 13.32 | 0.0778 | 0.047 |
500 | 26.4 | 3.4 | 0.1 | 3.5 | 86.4 | 7.63 | 16.5 | 0.0605 | 0.0366 |
8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable |
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 |
Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm 2 | mm | mm | mm | mm | mm | kg/m | | Ω/km | Ω/km |
25 | 6 | 4.5 | 0.1 | 2.3 | 43.9 | 1.57 | 2.02 | 0.927 | 0.727 |
35 | 6.9 | 4.5 | 0.1 | 2.4 | 46 | 1.75 | 2.38 | 0.668 | 0.524 |
50 | 8.2 | 4.5 | 0.1 | 2.4 | 48.8 | 2 | 2.85 | 0.4936 | 0.387 |
70 | 9.7 | 4.5 | 0.1 | 2.5 | 52.3 | 2.34 | 3.57 | 0.342 | 0.268 |
95 | 11.3 | 4.5 | 0.1 | 2.6 | 55.9 | 2.75 | 4.45 | 0.2464 | 0.193 |
120 | 12.8 | 4.5 | 0.1 | 2.7 | 59.4 | 3.16 | 5.32 | 0.1955 | 0.153 |
150 | 14.2 | 4.5 | 0.1 | 2.8 | 62.6 | 3.57 | 6.27 | 0.1587 | 0.124 |
185 | 15.9 | 4.5 | 0.1 | 2.9 | 66.4 | 4.07 | 7.45 | 0.1271 | 0.0991 |
240 | 18.3 | 4.5 | 0.1 | 3.1 | 72 | 4.82 | 9.25 | 0.0976 | 0.0754 |
300 | 20.4 | 4.5 | 0.1 | 3.3 | 77 | 5.71 | 11.28 | 0.0778 | 0.0601 |
400 | 23.2 | 4.5 | 0.1 | 3.4 | 83.2 | 6.78 | 13.86 | 0.0615 | 0.047 |
500 | 26.4 | 4.5 | 0.1 | 3.5 | 91.1 | 8.2 | 17.32 | 0.0487 | 0.0366 |
9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable |
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 |
Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm 2 | mm | mm | mm 2 | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | - | | | | | | | | |
35 | 6.9 | 5.5 | 0.1 | 2.4 | 50.3 | 2 | 2.63 | 0.868 | 0.668 |
50 | 8.2 | 5.5 | 0.1 | 2.5 | 53.3 | 2.26 | 3.11 | 0.641 | 0.4936 |
70 | 9.7 | 5.5 | 0.1 | 2.6 | 56.8 | 2.62 | 3.85 | 0.443 | 0.342 |
95 | 11.3 | 5.5 | 0.1 | 2.8 | 60.6 | 3.07 | 4.77 | 0.32 | 0.2464 |
120 | 12.8 | 5.5 | 0.1 | 2.9 | 64.1 | 3.49 | 5.65 | 0.253 | 0.1955 |
150 | 14.2 | 5.5 | 0.1 | 3 | 67.3 | 3.91 | 6.61 | 0.206 | 0.1587 |
185 | 15.9 | 5.5 | 0.1 | 3.1 | 71.2 | 4.44 | 7.81 | 0.164 | 0.1271 |
240 | 18.3 | 5.5 | 0.1 | 3.3 | 76.8 | 5.21 | 9.64 | 0.125 | 0.0976 |
300 | 20.4 | 5.5 | 0.1 | 3.3 | 81.3 | 6.1 | 11.66 | 0.1 | 0.0778 |
400 | 23.2 | 5.5 | 0.1 | 3.5 | 87.7 | 7.2 | 14.28 | 0.0778 | 0.0615 |
500 | 26.4 | 5.5 | 0.1 | 3.8 | 96 | 9.15 | 17.8 | 0.0605 | 0.0487 |
10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable |
Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 |
Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor |
mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
25 | | | | | | | | | |
35 | | | | | | | | | |
50 | 8.2 | 8 | 0.1 | 2.9 | 64.9 | 3.02 | 3.87 | 0.641 | 0.4936 |
70 | 9.7 | 8 | 0.1 | 3 | 68.4 | 3.42 | 4.65 | 0.443 | 0.342 |
95 | 11.3 | 8 | 0.1 | 3.1 | 72 | 3.89 | 5.59 | 0.32 | 0.2464 |
120 | 12.8 | 8 | 0.1 | 3.3 | 75.7 | 4.39 | 6.54 | 0.253 | 0.1955 |
150 | 14.2 | 8 | 0.1 | 3.3 | 78.7 | 4.85 | 7.55 | 0.206 | 0.1587 |
185 | 15.9 | 8 | 0.1 | 3.4 | 82.6 | 5.42 | 8.79 | 0.164 | 0.1271 |
240 | 18.3 | 8 | 0.1 | 3.5 | 88 | 6.22 | 10.66 | 0.125 | 0.0976 |
300 | 20.4 | 8 | 0.1 | 3.7 | 92.9 | 7.2 | 12.77 | 0.1 | 0.0778 |
400 | 23.2 | 8 | 0.1 | 3.9 | 99.3 | 8.38 | 15.46 | 0.0778 | 0.0615 |
500 | 26.4 | 8 | 0.1 | 4.2 | 107.6 | 10.15 | 18.85 | 0.0605 | 0.0487 |
FAQ:
1.Q: Is your company a manufacturer or a trade company?
A: We are cable manufacturer.
2. Q: Where is your factory located? How can I visit there?
A:Our factory is located in Ningjin City, Hebei Province, China. You can fly to Shijiazhuang airport directly. All our clients, from home or abroad, are warmly welcome to visit us!
3. Q: What is your sample policy?
A: Some of our samples are available for free, while others are available at a cost, which will be deducted from the purchase order.
4.Q: How does your factory do regarding quality control?
A: Quality is priority. We always attach great importance to quality controlling from the very beginning to the very end.
5. Q: I am very interested in your product, can you sent me your full catalog and pricing list?
A: We can select some popular products for you immediately. Please let us know your requirements so that we can send out the quotation to you.
Our Services
1. We guarantee to offer new advanced goods.
2. We'd like to send skilled personnel to the installing place to help offer technical consultant, quantity estimation and instruction,
installing, preliminary testing,and help start up running; and to answer for any defect of the product found in installing and run testing,
If there's something wrong with the product, we'll give our answer within 12 hours and get to the spot within 36 hours.
3.After installaton, We'll send skilled personnel to have the preliminary test and answer for any problems emerged. We take the whole charge of the fee needed in repairing,testing or retesting within the scope of our duty required in contract.
4.During the contract's period of validity,of the project must be started all over again or the goods can not be used at all which is resulted from
our faulty goods and improper files or mistakes made by our instructors, we'll change the goods at once without compensation and
take charge in all expenses of reinstallation.
주소:
Shijiazhuang Jianshebeidajiie 228 Donghaiguojidasha, Shijiazhuang, Hebei, China
사업 유형:
제조사/공장
사업 범위:
전기전자
회사소개:
Yiteng Cable Technology Hebei Co., Ltd.는 국내외 고객 모두에게 큰 찬사를 받은 전선과 케이블의 전문 제조업체입니다.
1.주요 제품:
알루미늄 합금 케이블;
베어 컨덕터(AAC, ACSR, AAC, ACAR);
ABC 케이블(공중 번들 케이블),
차폐형 케이블(컴퓨터 차폐형 케이블, 차폐형 제어 케이블, Armor로 차폐된 케이블),
전원 케이블(저/중/고전압의 PVC 및 XLPE 절연 케이블, 강철 테이프 및 강철 와이어 강화 케이블),
고무 케이블,
특수 케이블...
이 케이블은 송전 스테이션, 석탄, 철도, 농업, 부동산 등과 같은 공기, 지하 또는 공업에서의 송전용으로 사용할 수
있습니다. 2. 품질 규약 및 승인:
Yiteng이 있는 모든 케이블은 GB, IEC, BS, ASTM, DIN, VDE 이 공장은 ISO9001 및 ISO14001의 인증을 받았습니다. 또한, 당사의 케이블은 CCC, 중국 필수 인증 및 국제 텍스트 시스템 인증 등에 의해 승인되었습니다.
서비스 약속:
YITENG Cable의 비즈니스 철학은 언제나 "고객의 성공을 돕는" 것입니다. 우리는 글로벌 에이전트 및 고객과 전략적 협력을 수립함으로써 케이블 산업의 발전에 우리 자신과 우리의 자원을 투입합니다.
모든 고객을 위한
서비스 - 단순한 약속 이상의 것. 양질의 케이블을 제공하는 것 외에도, 서비스 팀은 항상 고객에게 전문 지식을 제공할 준비가 되어 있습니다.
모든 고객에게 제공하기 위해 최선을 다하는 YITENG 케이블:
- 경쟁력 있는 가격의 고품질 제품,
- 주문 수량 낮은 OEM 제품,
- 고객의 특정 요구 사항과 예산에 따른 맞춤형 설계,
- 빠른 배송,
유연한 비즈니스 거래
-20년 이상 근무한 최고 엔지니어 -
조화로운 동료와 고객 관계 -
모든 제품 100% 검사 -
포괄적인 애프터 서비스.
기업 문화:
품질에 따라 살아가고, 신용에 의해 발전합니다.
기대치를 넘어, 지속적으로 개선하고, 탁월성을 추구합니다.
고객을 위한 가치를 창출하고, 직원을 위한 행복을 만드십시오.